Dextran 10K

dextran 10,000 MW

wt%		log P (dynes/cm^2)

14.7		5.92
20.8		6.18
23.4		6.38
30.2		6.59
34.2		6.85

An equation that fits this data is the following.

log P = a + b * (wt%) ^ c

where a = 4.52, b = 0.28 and c = 0.60

Note that it should be applied only over the range of pressures measured.