PEG400

PEG400 Osmotic pressure data (atm)

Reference - https://doi.org/10.1002/pro.4573. Osmotic pressure was calculated from the water activity data in table S4. 

Wt%15 degrees C20 degrees C25 degrees C35 degrees C45 degrees C
53.693.743.653.703.71
108.558.528.178.248.23
1514.914.713.813.913.8
2023.222.621.021.021.0
2534.032.830.230.030.0
3048.145.942.041.541.2
3566.763.157.356.455.6
4091.986.377.776.274.8
4512511710410299.6
50172159141137133

 

PEG400 Osmotic pressure data (dyn/cm^2)

Reference - https://doi.org/10.1016/S0006-3495(97)78754-X

wt%     log P (dynes/cm^2)

2.5      6.3
5         6.55
10       6.93
15       7.14
20       7.33
25       7.5
30       7.65

An equation that fits this data is the following.

log P = a + b * (wt%) ^ c where a = 5.29, b = 0.73 and c = 0.34

Note that it should be applied only over the range of pressures measured.